COT is Inkbit’s dielectric material platform for complex RF components. Read the measured values with their sample, date, and frequency context before applying them to a design.

LOSS TANGENT / Df0.0013

At 100 GHz. Sample A, measured October 2026.

DIELECTRIC CONSTANT / Dk2.4

At 100 GHz. February 2026 datasheet measurement.

CHARACTERIZATION RANGE10–130 GHz

Fabry-Perot open resonator. A material test range, not a universal component rating.

COT dielectric constant and loss tangent versus frequency from 10 to 130 GHz. Dk is 2.4 and Sample A Df is 0.0013 at 100 GHz.
Source: COT dielectric constant and loss tangent measurement sheet. Loss tangent: Sample A, October 2026. Dielectric constant: February 2026 datasheet measurement.

MATERIAL / SIGNAL INTEGRITY

Start with the dielectric.

COT chemistry provides the material foundation. Geometry and operating conditions determine the response of the finished component.

Read the measurement conditions
INKBIT ARC / ENGINEERING PRINCIPLESCHEMATIC
ABC
A

Incident field

B

COT dielectric

C

Transmitted field

Conceptual geometry. Not to scale; not a measured radiation pattern.

INTERPRETING THE DATA

Keep material evidence
and system results distinct.

01

A dated sample result.

The updated sheet reports Df 0.0013 at 100 GHz for Sample A. The earlier datasheet reports 0.0018. These are separately reported measurements; this page does not claim a controlled process improvement or a guaranteed value for every manufactured part.

02

Bulk material and effective geometry.

The Dk value describes material characterization. A lattice or graded structure has an effective dielectric response shaped by its geometry. Use the relevant material data, cell design, and frequency in your electromagnetic model.

03

Validate the component you will use.

Loss tangent does not directly specify antenna gain, filter insertion loss, radome transmission, or field performance. Those outcomes depend on the complete design and its operating conditions. Agree on simulation inputs and acceptance measurements with Inkbit.

SOURCE DOCUMENTS

Updated dielectric measurement sheet

Sample A loss measurement, October 2026; Dk measurement, February 2026.

COT technical datasheet

Earlier published material reference. Its historical loss value remains as issued.

From material properties to RF applications

Explore component-specific evidence and engineering review paths.

INDUSTRY CONTEXT

Where these capabilities fit.

Industry guideDielectric components for defense RF systems.Industry guideDielectric components for satellite communications.Industry guideShape the signal for industrial sensing.Industry guideCustom dielectric components for radar systems.Industry guideDielectric components for automotive radar.Industry guideDielectric lenses for telecom and mmWave backhaul.